Sollae Systems ezTCP CSE-H55N2 Industrial RS-422/RS-485 to Ethernet Converter
€114,00 EUR
Free worldwide shipping
Free returns
Carbon neutral
Secure payments
Professional-Grade Multi-Drop Serial Networking with IPv4/IPv6 Dual Stack Support: Transform your RS-422/RS-485 serial networks into IP-enabled infrastructure with industrial-grade reliability and advanced IPv4 and IPv6 support.
The Sollae Systems CSE-H55N2 is an industrial-grade RS-422/RS-485 to Ethernet converter designed for demanding multi-drop serial networks. With support for both IPv4 and IPv6, extreme temperature range (-40°C to +85°C), and advanced features like SSL/TLS security and multiple simultaneous connections, the CSE-H55N2 delivers enterprise-level performance for mission-critical industrial automation, SCADA, and building management systems.
Why Choose the CSE-H55N2?
🔄RS-422/RS-485 Versatility
Support for both RS-422 (full-duplex, point-to-point or multi-drop) and RS-485 (half-duplex, multi-drop up to 32 devices). One converter handles all your long-distance serial networking needs up to 4,000 feet.
🌐Future-Proof IPv6 Support
Full IPv4/IPv6 dual stack implementation with stateless and stateful (DHCPv6) address auto-configuration. Ready for modern networks and future IPv6 deployments with ICMPv6, TCPv6, and UDPv6 support.
🏭Industrial-Grade Reliability
Extreme temperature range (-40°C to +85°C) and enhanced noise immunity make this converter perfect for harsh industrial environments. Upgraded from CSE-H55N with improved stability against electrical damage and noise on RS-422/485 lines.
🔒Enterprise Security
Built-in SSL/TLS encryption, IP/MAC filtering, and password protection ensure your serial data remains secure across the network. Perfect for sensitive industrial control applications.
🔄Multiple Connection Support
Monitor and control from multiple locations simultaneously. Multiple clients can connect to a single CSE-H55N2 for distributed monitoring and control applications (firmware v2.3A or later).
⚡High-Speed Performance
RS-422/RS-485 support up to 230.4 kbps ensures fast, reliable data transfer for even the most demanding serial applications. Long-distance capability up to 4,000 feet (1,200m).
🛡️Enhanced Protection
Embedded 3.9kΩ biasing resistors and TVS (Transient Voltage Suppression) protection on all serial lines. Over-current, reverse voltage, and surge protection on power input.
🎯Flexible Configuration
Configure via Ethernet (ezManager), serial port, AT commands, or Telnet. Choose the method that works best for your deployment scenario. Mobile apps available for iOS and Android.
CSE-H55N2 Technical Specifications
Serial Interface
Physical Interface:
Type:RS-422 or RS-485 (software selectable)
Connector:6-pin Terminal Block (3.5mm pitch)
Protection:Embedded 3.9kΩ biasing resistors and TVS on all lines
Advantages:Full-duplex, simultaneous bidirectional communication
Use Cases:Long-distance point-to-point links, distributed monitoring
RS-485 Mode (Half-Duplex):
Multi-Drop Network:Up to 32 devices on one bus
Maximum Distance:4,000 feet (1,200m)
Topology:Daisy-chain (linear bus)
Advantages:Multiple devices on single cable pair, cost-effective
Use Cases:Modbus RTU, Profibus, BACnet MS/TP, building automation
Built-in Protection:
3.9kΩ Biasing Resistors:Embedded on all serial lines for idle state stability
TVS Protection:Transient Voltage Suppression protects against electrical spikes
Enhanced Noise Immunity:Upgraded design from CSE-H55N for improved stability
IPv6 Dual Stack Implementation
The CSE-H55N2 is fully IPv6-ready with comprehensive support:
IPv6 Features:
Full IPv4/IPv6 dual stack operation
Stateless address auto-configuration (SLAAC)
Stateful address configuration (DHCPv6)
IPv6 fragmentation support
ICMPv6, TCPv6, UDPv6 protocols
Seamless IPv4/IPv6 interoperability
Why IPv6 Matters:
Future-proof your infrastructure
Larger address space eliminates NAT complexity
Improved security with IPsec integration
Better support for IoT devices
Simplified network configuration
Multiple Connection Support
Simultaneous Monitoring (Firmware v2.3A+):
Multiple TCP clients can connect to one CSE-H55N2 simultaneously
Perfect for distributed monitoring applications
Each client receives the same serial data
Ideal for redundant monitoring systems
No additional hardware required
Use Cases:
Multiple operators monitoring the same equipment
Redundant data logging systems
Distributed SCADA architectures
Multi-site monitoring applications
Backup monitoring stations
SSL/TLS Security
Secure Socket Layer Protection:
Encrypt serial data over the network
Protect sensitive information in transit
Industry-standard SSL/TLS protocols
Certificate-based authentication
Prevents eavesdropping and tampering
Security Features:
IP address filtering (whitelist/blacklist)
MAC address filtering
Password-protected configuration
Secure firmware updates
Access control lists
Packet Fragmentation Control
Separator Settings:
Define custom packet delimiters
Control when data is transmitted over network
Optimize for different protocols and applications
Reduce network overhead
Improve application-level parsing
Data Frame Interval:
Configure timeout for packet assembly
Balance real-time performance vs. network efficiency
Adjustable from 0ms (immediate) to custom values
Optimize for your specific application
Telnet COM Port Control (RFC 2217)
Remote Serial Port Control:
Change serial parameters remotely over network
Adjust baud rate, parity, data bits, stop bits
Control flow control settings
Monitor serial port status
No physical access required
Benefits:
Remote troubleshooting and diagnostics
Dynamic serial parameter adjustment
Centralized serial port management
Reduced site visits and maintenance costs
Dynamic DNS (DDNS) Support
Always Accessible:
Automatic DNS updates when IP address changes
Use hostname instead of IP address
Perfect for dynamic IP environments
Supports major DDNS providers
Simplified remote access
PPPoE Support
Direct Internet Connection:
Connect directly to DSL/cable modems
No router required for simple deployments
Automatic authentication and connection
Ideal for remote installations
Reduced hardware costs
AT Command Mode
Patented Dynamic Control:
Change connection parameters at runtime
Establish/terminate connections via serial commands
No device reboot required
Perfect for applications requiring dynamic connectivity
Unique Sollae Systems technology
AT Command Capabilities:
Configure IP addresses and ports
Establish TCP connections
Control DHCP and PPPoE
Set DNS servers
Modify timeout values
Save settings to flash memory
Software Suite
ezManager - Configuration Utility
Comprehensive Management Tool for Windows:
Features:
No installation required (portable application)
Automatic device discovery via MAC or IP address
Intuitive graphical interface
Real-time status monitoring
Firmware update management
Configuration backup and restore
Simple test utility included
Batch configuration for multiple devices
Configuration Methods:
Via Ethernet (LAN)
Via Serial port
Remote configuration via Telnet
ezVSP - Virtual Serial Port Driver
Windows Virtual COM Port Driver:
Features:
Creates virtual COM ports on Windows PC
Legacy applications work without modification
Supports multiple virtual ports
Automatic reconnection on network interruption
Compatible with Windows 7/8/10/11
No application changes required
How It Works:The CSE-H55N2 appears as a local COM port on your Windows PC. Your existing serial software communicates with the virtual port, and ezVSP handles all network communication transparently.
ezTerm - Communication Test Tool
Simple TCP/IP Testing:
Features:
Quick TCP/IP communication testing
Both TCP and UDP support
Server and client modes
Hex and ASCII data display
Data logging capabilities
Perfect for troubleshooting
Smartphone Applications
Mobile Configuration:
ezManager app available for iOS and Android
Configure devices from your smartphone or tablet
Monitor status remotely
Perfect for field installations
Free download from app stores
RS-485 Network Configuration Guide
Termination Resistors
RS-485 networks require 120Ω termination resistors at both ends of the bus:
Enable terminationon the first and last devices only
Disable terminationon all middle devices
Improper termination causes communication errors and reflections
Use quality 120Ω resistors rated for your application
Biasing Resistors
The CSE-H55N2 includes embedded 3.9kΩ biasing resistors:
Purpose:Maintain idle state voltage levels on the bus
Benefit:Prevents false triggering and improves noise immunity
Built-in:No external biasing resistors required
Wiring Best Practices
Cable Selection:
Usetwisted pair cable(Cat5e or better, or dedicated RS-485 cable)
Shielded cablerecommended in electrically noisy environments
Characteristic impedance:120Ω for proper termination
Topology:
Usedaisy-chain topology(linear bus)
Avoidstar topology(creates reflections)
Keepstubsshorter than 1 meter
Maximum bus length:4,000 feet (1,200m)
Grounding:
ConnectGNDat both ends (pins 3 and 6)
Maintainproper groundingto prevent ground loops
Usesingle-point groundwhen possible
Shield grounding:Ground shield at one end only to prevent ground loops
Multi-Drop Addressing
For RS-485 networks with multiple devices:
Each device needs aunique address(configured in serial device)
Classic RS-485 multi-drop topology with up to 32 devices.
Frequently Asked Questions
Q: What's the difference between the CSE-H55N2 and the CSE-H53N? A: The CSE-H55N2 supports RS-422/RS-485 (long-distance, multi-drop capable), while the CSE-H53N supports RS-232 only (short-distance, point-to-point). The CSE-H55N2 is ideal for industrial multi-drop networks up to 4,000 feet, while the CSE-H53N is for simple RS-232 device networking.
Q: What's the difference between the CSE-H55N2 and the original CSE-H55N? A: The CSE-H55N2 is an upgraded version with improved stability against noise and electrical damage on RS-422/485 lines. It features enhanced protection with embedded TVS and better noise immunity. The software functionality remains the same.
Q: Can I use this for Modbus RTU networks? A: Yes! The CSE-H55N2 is perfect for Modbus RTU over RS-485. It acts as a transparent bridge, allowing your Modbus master to communicate with up to 32 Modbus slave devices over Ethernet. The converter doesn't interpret Modbus protocol—it simply passes data transparently.
Q: How many devices can I connect on an RS-485 network? A: Standard RS-485 supports up to 32 devices (unit loads) per bus. The CSE-H55N2 counts as one device. For larger networks, use RS-485 repeaters to extend beyond 32 devices.
Q: Do I need termination resistors? A: Yes, RS-485 networks require 120Ω termination resistors at both ends of the bus (first and last devices). The CSE-H55N2 includes embedded biasing resistors but you must add external termination resistors at the bus ends.
Q: What's the maximum cable distance? A: RS-422/RS-485 supports up to 4,000 feet (1,200m) at lower baud rates. At maximum baud rate (230.4 kbps), distance may be limited to 100-300 feet depending on cable quality and environmental noise.
Q: Does the CSE-H55N2 support IPv6? A: Yes! The CSE-H55N2 has full IPv4/IPv6 dual stack support with both stateless (SLAAC) and stateful (DHCPv6) address auto-configuration. It's fully ready for modern IPv6 networks.
Q: Can multiple computers access the serial network simultaneously? A: Yes, with firmware version 2.3A or later, multiple TCP clients can connect to the CSE-H55N2 simultaneously. All connected clients receive the same serial data, perfect for distributed monitoring applications.
Q: What is AT Command mode? A: AT Command mode is a patented Sollae Systems feature that allows you to control TCP/IP connections dynamically via serial AT commands. You can establish connections, change IP addresses, modify ports, and configure network parameters without rebooting the device.
Q: How do I configure the CSE-H55N2? A: You have multiple options: (1) ezManager via Ethernet, (2) ezManager via serial port, (3) AT commands via serial terminal, or (4) Telnet. Choose the method that works best for your deployment.
Q: What is the default IP address? A: The default IP address is 10.1.0.1 with subnet mask 255.0.0.0. The default local port is 1470, serial type is RS-485, and the default serial settings are 19,200 bps, 8-N-1.
Q: Can I use this outdoors? A: The CSE-H55N2 is rated for industrial temperatures (-40°C to +85°C) but is not waterproof. For outdoor use, install in a weatherproof enclosure (NEMA 4X or IP65 rated).
Q: Does it support SSL/TLS encryption? A: Yes, the CSE-H55N2 includes SSL/TLS support for secure data transmission over the network. This protects your serial data from eavesdropping and tampering.
Q: What operating systems are supported? A: The device works with any OS that supports TCP/IP (Windows, Linux, macOS, Unix, etc.). The ezManager and ezVSP utilities are Windows-only, but you can configure via Telnet or AT commands from any platform.